Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation

2003

Abstract Purpose To evaluate deviations in the axis (intended versus achieved) and postoperative astigmatism after implantation of an Artisan toric phakic intraocular lens (IOL). Setting University Eye Hospital, Mainz, Germany. Methods This prospective study comprised 29 eyes with high ametropia and astigmatism. All eyes had uneventful implantation of a toric phakic IOL through a superior scleral tunnel incision at 12 o’clock. After a minimum of 6 months, the uncorrected visual acuity (UCVA), best correct visual acuity, refraction, and astigmatism were analyzed in all eyes. A multivariate analysis of postoperative astigmatism was performed. Results After a follow-up of at least 6 months, 95…

AdultMaleRefractive errorVisual acuityRotationgenetic structuresmedicine.medical_treatmentEmmetropiaIntraocular lensPhakic intraocular lensLens Implantation IntraocularmedicineHumansPostoperative PeriodProspective StudiesDioptreLenses Intraocularbusiness.industryAstigmatismEquipment DesignMiddle AgedRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresToric lensOphthalmologyMeridian (perimetry visual field)OptometryFemaleSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Iris-fixated toric phakic intraocular lens: Three-year follow-up

2006

Purpose To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. Methods A prospective clinical trial of 40 eyes of 23 patients with high ametropia and astigmatism was conducted. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, astigmatism, intraocular pressure, slitlamp biomicroscopy, and indirect ophthalmoscopy were measured preoperatively and postoperatively. Results Of t…

AdultMalemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIrisIntraocular lensAstigmatismRefraction OcularPhakic intraocular lensOphthalmoscopyPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineHumansMedicineProspective StudiesIntraoperative ComplicationsIntraocular PressureDioptremedicine.diagnostic_testbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresOphthalmoscopyToric lensOphthalmologyTreatment OutcomeFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Endothelial cell loss after toric iris-fixated phakic intraocular lens implantation: three-year follow-up.

2007

ABSTRACT PURPOSE: To study quantitative changes in endothelial cell count after implantation of the toric iris-fixated phakic intraocular lens. METHODS: A prospective, non-randomized, self-controlled clinical trial was conducted of 40 eyes (28 myopic, 12 hyperopic) of 23 patients with high ametropia and astigmatism. Non-contact computer-assisted endothelial microscopy was performed before and I1 2, and 3 years after surgery. RESULTS: In the myopic group, mean preoperative endothelial cell count was 3179±531 cells/mm p 2 (range: 1800 to 3900 cells/mm2). The mean intraindividual endothelial cell loss was -1.83±2.25% (range: -9.09% to 0%) in the first year; -1.83+2.95% (range: -7.74% to 3.80%)…

AdultMalemedicine.medical_specialtyTime FactorsIrisCell CountAstigmatismPhakic intraocular lensEndothelial cell countCorneal DiseasesPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineMedicineHumansProspective Studiesbusiness.industryEndothelium CornealSuture TechniquesMiddle Agedmedicine.diseaseCell lossRefractive Surgical ProceduresEndothelial stem cellOphthalmologySurgeryFemalebusinessFollow-Up StudiesJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator

2013

To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…

AdultMicrosurgeryOptics and PhotonicsPhakic Intraocular LensesVisual acuityAdolescentgenetic structuresComputer sciencemedia_common.quotation_subjectVisual AcuityPhakic intraocular lensPupilYoung AdultLens Implantation IntraocularOptical transfer functionmedicineHumansContrast (vision)Prospective StudiesAdaptive opticsVision OcularSimulationDioptremedia_commonAberrometryStrehl ratioeye diseasesRefractive Surgical ProceduresOphthalmologysense organsmedicine.symptomAmerican Journal of Ophthalmology
researchProduct

Contrast sensitivity after LASIK flap creation with a femtosecond laser and a mechanical microkeratome

2007

ABSTRACT PURPOSE: To compare the effects on contrast sensitivity of the IntraLase femtosecond laser for flap creation (IntraLASIK) and standard LASIK for myopia. METHODS: Two hundred eyes of 100 consecutive patients underwent LASIK treatment using the VISX S2 laser system. The femtosecond laser (15 kHz IntraLase) was used for flap creation in 100 eyes (50 patients) and a mechanical microkeratome (Carriazo-Barraquer) was used in 100 eyes (50 patients). Best spectacle-corrected contrast sensitivity was measured before and 6 months postoperatively in the IntraLASIK and mechanical LASIK groups. The IntraLASIK and mechanical LASIKinduced changes in contrast sensitivity were compared under photop…

Adultmedicine.medical_specialtygenetic structuresMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituSurgical Flapslaw.inventionContrast SensitivitylawMicrokeratomeOphthalmologymedicineHumansContrast (vision)media_commonbusiness.industryLASIKEquipment DesignRefractive ErrorsLasereye diseasesRefractive Surgical ProceduresSurgeryOphthalmologyTreatment OutcomeFemtosecondSurgerysense organsbusinessSensitivity (electronics)Follow-Up StudiesPhotopic vision
researchProduct

Incisional Keratotomy to Toric Intraocular Lenses: An Overview of the Correction of Astigmatism in Cataract and Refractive Surgery

2003

Lenses Intraocularmedicine.medical_specialtybusiness.industrymedicine.medical_treatmentAstigmatismCataract ExtractionAstigmatismmedicine.diseasePhotorefractive KeratectomyRefractive Surgical ProceduresCorneaOphthalmologyPostoperative ComplicationsLens Implantation IntraocularIntraocular lensesOphthalmologyRefractive surgerymedicineHumansLasers ExcimerbusinessKeratotomy RadialInternational Ophthalmology Clinics
researchProduct

Graphic representation of data resulting from measurement comparison trials in cataract and refractive surgery.

2003

* BACKGROUND AND OBJECTIVES: The evaluation of new diagnostic measurement devices allows intraindividual comparison with an established standard method. However, reports in journal articles often omit the adequate incorporation of the intraindividual design into the graphic representation. * PATIENTS AND METHODS: This article illustrates the drawbacks and the possible erroneous conclusions caused by this misleading practice in terms of recent method comparison data resulting from axial length measurement in 220 consecutive patients by both applanation ultrasound and partial coherence interferometry. * RESULTS: Graphic representation of such method comparison data should be based on boxplots…

LightConcordancemedicine.medical_treatmentCataract ExtractionDiagnostic Techniques Ophthalmologicalcomputer.software_genreEyeCataractOpticsRefractive surgeryComputer GraphicsMedicineHumansIntraindividual comparisonProspective StudiesGraphicsRepresentation (mathematics)Mathematical ComputingUltrasonographybusiness.industryAxial lengthRefractive ErrorsRefractive Surgical ProceduresOphthalmologyInterferometryMethod comparisonPartial coherence interferometryData Interpretation StatisticalArtificial intelligencebusinesscomputerNatural language processingOphthalmic surgery, lasersimaging : the official journal of the International Society for Imaging in the Eye
researchProduct

Optical Quality Comparison of Conventional and Hole-Visian Implantable Collamer Lens at Different Degrees of Decentering

2012

To compare the optical quality of implantable Collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering.Experimental laboratory investigation.Wavefront aberrations of the -3, -6, and -12 diopter (D) V4b and -3, -6, and -12 D V4c ICLs were measured in 3 conditions-centered and decentered 0.3 and 0.6 mm-at 3-mm and 4.5-mm pupils. The root mean square of total higher order aberrations, trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, point spread function and simulated retinal images of ICLs were calculated from the wavefront aberrations for each ICL and all conditions of decenteri…

Optics and PhotonicsPhakic Intraocular LensesCorneal Wavefront Aberrationgenetic structuresZernike polynomialsComa (optics)In Vitro TechniquesAstigmatismArtificial Lens Implant MigrationProsthesis DesignPhakic intraocular lensRetinasymbols.namesakeOpticsLens Implantation IntraocularmedicineHumansDioptreWavefrontPhysicsbusiness.industryAstigmatismModels Theoreticalmedicine.diseaseeye diseasesRefractive Surgical ProceduresOphthalmologySpherical aberrationAberrations of the eyesymbolsbusinessAmerican Journal of Ophthalmology
researchProduct

A new trifocal corneal inlay for presbyopia

2021

[EN] Corneal inlays (CIs) are the most recent surgical procedure for the treatment of presbyopia in patients who want complete independence from the use of glasses or contact lenses. Although refractive surgery in presbyopic patients is mostly performed in combination with cataract surgery, when the implantation of an intraocular lens is not necessary, the option of CIs has the advantage of being minimally invasive. Current designs of CIs are, either: small aperture devices, or refractive devices, however, both methods do not have good performance simultaneously at intermediate and near distances in eyes that are unable to accommodate. In the present study, we propose the first design of a …

genetic structuresComputer sciencemedicine.medical_treatmentScienceVisual AcuityBiophysicsFOS: Physical sciencesIntraocular lens01 natural sciencesArticle010309 opticsCornea03 medical and health sciences0302 clinical medicineRefractive surgery0103 physical sciencesmedicineHumans03.- Garantizar una vida saludable y promover el bienestar para todos y todas en todas las edadesIn patientAdaptive opticsMultidisciplinaryInlayVision TestsQRPresbyopiaPresbyopiaCataract surgerymedicine.diseasePhysics - Medical PhysicsCorneal inlayeye diseasesRefractive Surgical ProceduresTreatment OutcomeOptics and photonicsPreclinical researchFISICA APLICADA030221 ophthalmology & optometryOptometryMedicineMedical Physics (physics.med-ph)sense organsPhysics - OpticsOptics (physics.optics)
researchProduct

Binocular vision alterations after refractive and cataract surgery: a review.

2018

To review binocular and accommodative disorders documented after corneal or intraocular refractive surgery, in normal healthy prepresbyopic patients. A bibliographic revision was performed; it included works published before 1st July 2017 where accommodation and/or binocularity was assessed following any type of refractive surgical procedure. The search in Pubmed yielded 1273 papers, 95 of which fulfilled the inclusion criteria. Few publications reporting binocular vision and/or accommodative changes after refractive surgery in normal subjects were found. The reduction in fusional vergence is the most frequently reported alteration. Anisometropia is an important risk factor for postoperativ…

genetic structuresmedicine.medical_treatmentUlls -- Acomodació i refraccióEstrabismeCataract Extraction:Ciències de la visió::Optometria::Visió binocular [Àrees temàtiques de la UPC]:Ciències de la visió::Optometria::Acomodació i refracció [Àrees temàtiques de la UPC]Eye--Accommodation and refraction03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRefractive surgerymedicineDiplopiaHumansAnisometropiaVision Binocularbusiness.industryVision TestsCataractes -- CirurgiaFusional vergenceAccommodation OcularGeneral MedicineCataract surgerymedicine.diseaseVisió binoculareye diseasesRefractive Surgical ProceduresStrabismusContact lensOphthalmologyAccommodative convergenceCataract -- Surgery030221 ophthalmology & optometryOptometryBinocular visionbusinessBinocular visionAccommodation030217 neurology & neurosurgeryActa ophthalmologica
researchProduct